HA Manual
ACRONYMS AND ABBREVIATIONS
ACRONYMS
ACE
Ancillary Control Equipment
APS
Application Support Sub-layer
CIE
Control and Indicating Equipment
HA
Home Automation
IAS
Intruder Alarm Systems
WD
Warning Device
ZCL
ZigBee Cluster Library
SAS
Startup Attribute Set
Start Up Parameters
Short Address: 0xFFFF
E PANiD: 0x0000000000000000
PAN ID: 0xFFFF
Channel Mask
All channels in frequency band. If needed, the power transmitted by the device on channel 26 can be lowered ply with FCC regulations.
Protocol Version
0x02 (ZigBee Specification revision 17 (2007) and later).
Stack Profile
1 (ZigBee Feature Set) or 2 (ZigBee PRO Feature Set).
Startup Control
3 (three) if missioned, so it will work by association when mand is indicated by button press sequence.
0 (Zero) missioned. Indicates that the device should consider itself a part of work indicated by the ExtendedPANId attribute. In this case it will not perform any explicit join or rejoin operation.
Trust Center Address
0x0000.
Master Key
NULL
Network Key
NULL.
Default Trust Center Link Key
0x5A 0x69 0x67 0x42 0x65 0x65 0x41 0x6C 0x6C 0x69 0x61 0x6E 0x63 0x65 0x30 0x39
Note: The Link Key is listed in little-endian format.
Use Insecure Join
0x01 (True). This flag enables the use of insecure join as a fallback case at startup time.
Join Parameters
ScanAttempts
At boot time or when instructed to join work, the device should make up to three (3) scan attempts to find a ZigBee Coordinator or Router to associate with. If
it has not missioned, this means that when the user presses a button or uses another methodology to get it to join work, it will scan through all of the
channels up to three times to find work that allows joining. If it has already missioned, it should scan up to three times to find its work to join.
TimeBetweenScans
(1 second) Determines the number of seconds between each essful scan attempt
Network Rejoin
A device may attempt to rejoin for a period o