GZKS20型高效纤维过滤器改造实例
辛惠芳作者介绍:辛惠芳,女,本科,工程师,从事环境检测研究
(中国铝业山西分公司水电分厂山西河津 043300)
摘要:GZKS20型高效纤维过滤器是水电分厂处理工业废水的主要设备,但由于所处理水质差造成原有设备故障频发,使废水处理过程不能顺利进行。本文通过对实际运行过程中出现的故障进行研究,找出了原因所在,并通过改造实现了过滤器的稳定运行。
关键词:过滤器;故障;改造
Transform instance of GZKS20 high-efficiency fiber filter
XIN Hui-fang
(Water and Electricity Branch Factory of Shanxi pany, Aluminum copporation of China, Shanxi 043300)
Abstract: GZKS20 high-efficiency fiber filter is the main equipment of Water and Electricity Branch Factory of Shanxi pany which was used to treat the waste water. However, due to poor water quality, frequent equipment failures are high frequency, so that waste water treatment process can not proceed smoothly. In this paper, the reason of equipment failures was analyzed and the fiber filter was improved. The improved fiber filters can operation stably to treat the waste water.
Key words: Filter; Failure; Modification
1 前言
山西分公司水电分厂排水车间工业废水处理站担负着全厂工业废水的回收、处理、回用及达标外排任务,原有流程中没有过滤装置,为了降低回用水中悬浮物,为氧化铝生产提供合格的回用水,2000更新改造新增4台GZKS20型高效纤维过滤器,滤后水进入工业回用泵房水池,供氧化铝生产使用。投运2月内运行正常,出水水质悬浮物SS≤10mg/L,满足生产工艺要求,但随着运行时间的增加,过滤器开始出现故障,表现是:过水能力下降、顶板上升不到位、箱体内压增加引起风机跳停。半年后,由于过滤器故障频繁发生,且过水能力严重下降,停止运行。经过检查发现,引起上述问题的原因是来水水质较差
造成过滤器滤料板结,后对过滤器进行了一次大修,更换了滤料,并在顶板及上孔板四周加装了导向轮,以便使顶板能顺利上升,但再次投入运行不到3个月,同样问题出现,同时还发生了箱体被顶裂现象,再次停运,等待更新。2007年7月,为了在一月内实现工业废水达标排放,本人与过滤器发明人共同协商制定了改造方案,利用1个月的时间对其进行了改造,效果非常好,投运近2个月,使用正常,未发生任何故障。
2 GZKS20型高效
GZKS20 型高效纤维过滤器改造实例 来自淘豆网m.daumloan.com转载请标明出处.