上海中广核技术产业研发中心工程
监理实施细则
(地下室人防工程)
专业监理工程师:
总监理工程师:
上海申海建设监理有限公司
中广核技术产业研发中心项目监理部
2010年8月
目录
一、工程概况····················································································································3
二、(人防区域)设计要求·······························································································3
三、监理依据···················································································································4
四、监理目标····················································································································4
五、监理准备工作············································································································5
六、监理工作流程············································································································5
七、施工难点及监理重点······························································································11
八、监理预控要点··········································································································12
九、监理工作方法、措施及工程控制要点·································································12
一、工程概况
:上海中广核技术产业研发中心
:包括地下室、产业中心、研发中心、图文中心、行政中心、会议中心、服务中心、门卫8个子项目
:
建设单位:上海中广核工程科技有限公司
设计单位:同济大学建筑设计研究院(集团)有限公司;
监理单位:上海申海建设监理有限公司
施工单位:广厦建设集团有限责任公司
:上海市闵行区紫竹科学园区东川路南、淡水河东、紫星路北,吴泾镇工—52号地块
:总建筑面积109832m2,其中地下室建筑面积32112m2(人防防护单元建筑面积2000m2),建筑基底面积18595 m2
:地下一层、地上4及5层,建筑最高度24m
:抗震设防烈度7度、设计使用年限50年、安全等级二级
二、(人防区域)设计要求
:①~⑧/~轴内设置人防地下室,建筑面积2000m2,地下室顶板室外部分覆土厚度450mm。
:甲类、核武器抗力级别6级、常规武器抗力级别6级,防化等级丙级,防水等级二级。
:防护单元建筑面积2000m2,人防使用面积1900 m2、掩护面积1400 m2掩护人数1400人。
:三个出入口,战时主要出入口利用室外汽车坡道设置;战时次要出入口利用人防地下室东北侧楼梯,人防区西侧设置一个战时人员疏散口
、排风口:排风口设防爆波活门,扩散室采用超压排风方式;进风口设进风竖井,防爆波活门、扩散室、除尘滤毒室和进风机房。
:共计封堵4处:钢筋砼预制梁临战封堵2处、密闭通道1处(不计入临战转换工作量)、钢筋砼防护密闭门临战封堵1处。
,抗渗等级P6。
三、监理依据
1人防基础结构设计图纸,以及有关图纸会审纪要、设计变更、技术核定单等。
、合同及补充协议。
、规定。
、验
中广核地下室人防工程监理实施细则 来自淘豆网m.daumloan.com转载请标明出处.