Technical Information Electrochemical Carbon-monoxide Sensor NE-CO-SI
(1) Design Features
Quick response and high sensitivity Good linearity Good selectivity Low power consumption for battery operation
(2) Specifications
[Sensitivity Characteristics]
Detection Gas Carbon-monoxide Detection Range 0 1,000 ppm Maximum Overload 1,500ppm Output Signal 55 10 nA/ppm Repeatability 2 % Typical Baseline Range (pure air) 5 ppm Typical Response Time (t90) 30 seconds Baseline Shift (- 20 50oC) 10 ppm Long Term Output Drift 5% / year Expected Life Time 2 years