第一章MG200/500-QWD型采煤机电气系统总论···············1 第一节概述···························1第二节MG200/500-QWD型采煤机电气控制系统的原理·········4第二章MG200/500-QWD型采煤机电控系统·············10第一节采煤机电控箱····················10第二节可编程控制器····················15第三节无线电遥控发射机····················20第四节端头控制站······················21第五节其它电气元件······················22第三章MG200/500-QWD型采煤机变频调速控制系统·······24第一节变频调速控制箱······················24第四章MG200/500-QWD型采煤机电气系统附件··········35第一节电动机···························35第二节电缆系统·······················35第五章MG200/500-QWD型采煤机电气系统操作············36第六章电气控制系统故障分析及处理··············40第一节电气系统常见故障的分析及处理··············40第二节变频器的常见故障分析及维修··············42第一章MG200/500-QWD型采煤机电气系统总论概述一、MG200/500-QWD型电牵引采煤机电气系统特点MG200/500-QWD型电牵引采煤机是为适应煤矿倾斜煤层工作面的需要而开发研制的新型双滚筒采煤机。该机电气系统主要特点有:采用四象限运行交流变频调速系统,适应电动和发电两种工作状态,牵引能力强;采用两个变频器分别拖动两个牵引电机,即“一拖一”工作方式;具有变频器时序控制机械制动器电路,系统起动转矩大,停止平稳;(PLC)为核心,系统可靠性高;,采煤机控制操作方便灵活;,可对系统状况进行较全面的监测;,提供全中文显示界面,系统参数显示全面准确;,有助于分析查找系统故障原因;。二、电气系统组成、适用环境和功能本机电气系统是为MG200/500-QWD型电牵引采煤机配套而专门研制的,它分为电气控制系统和变频调速系统两个部分。。整台采煤机的机械动力由两台200kW、1140V型号为YBCS4-200截割电机,两台40kW、380V型号为YBQYS-、1140V型号为YBRB-。适用环境:周围介质温度在-10℃~+35℃;周围空气的相对湿度不大于95%;不存在腐蚀金属和破坏绝缘的气体;有甲烷或爆炸性煤尘的采煤工作面。本采煤机电气系统具有下列操作、控制、保护及显示功能:,在采煤机上完成采煤机的起动、停止(兼闭锁);,在采煤机上完成工作面输送机的停止(兼闭锁);、右截割电机的温度监测和135℃、155℃热保护;、右截割电机的功率监测和恒功率自动控制、过载保护;、遥控器、-QWD型采煤机电气控制系统图引操作;、右摇臂的升降;;,提供操作步骤的提示,实时显示截割电机的功率和温度、牵引电机的电流、采煤机的牵引给定速度等工作参数;,共可记忆显示最近50个时间点的工作参数;;、输出频率或输出电流、故障等显示。。+12V,非本安+12V、+24V等。(1)非本安电源模块的型号为YM9854,输入由控制变压器220V、,输出有非本安F+12V、S+24V两种。其中F+12V作为电控箱操作及电控盒PA1、PA2、PA6的电源;S+24V作为GP显示器及截割电机电流互感器的电源。(2)本安12V电源的型号为MCDX-1,、,作为电控盒PA1、PA6及端头站的电源(3)非本安F+24V电源由控制变压器28V、4A绕组输出经
500、600电气说明书(采煤机g7变频器) 来自淘豆网m.daumloan.com转载请标明出处.