接触网施工安全操作规程
,应设专人监护,防止侵限刮碰列车。
。
,应清理施工料具,确认不影响行车后方可撤离施工现场。如果是既有接触网改造工程,施工结束后马上送电开通的,必须等首列电力机车通过后方可撤离。
《铁路基本作业施工安全技术规程》(TB10301);有关轨行车辆的规定外,尚应符合下列安全要求:
1非作业运行时,作业平台上不得有人。
2作业架升、降时不得上下人。
3当邻线未封锁时,作业车任何部位不得侵入邻线建筑限界。
4作业人员在作业平台上安装作业时,不得升、降、旋转作业平台。
5作业车的作业平台应降到安全高度后方可运行。
6作业平台的控制,必须专人控制。
:
1应指定车梯负责人,每辆车梯推扶人员不得少于4人,车梯上的作业人员不得超过2人。
2在铁路上使用车梯作业时,材料、工机具等不得放置在工作平台上。
3在轨道电路区段上使用车梯时,车梯的车轮与钢轨间应采取可靠的绝缘措施。
4不同接触线高度的接触网施工地点,应使用配套高度的车梯。
5车梯应按计划上道,禁止非计划转道。
6当邻线有列车通过时,作业人员应停止车梯作业。
7当车梯在曲线上或遇大风时,车梯负责人和推扶车梯人员应采取防止车梯倾倒的措施;遇6级以上强风、浓雾等恶劣天气应停止作业。
8车梯在地面上推动时,工作台上不得有人停留。
9车梯上的作业人员不得将安全带系在车梯工作台框架上。
10隧道内和夜间施工时,车梯应在行车方向侧面悬挂黄色反光标志牌。
11车梯搬离线路存放时,应采取措施防止其侵入铁路基本建筑限界。
12使用车梯进行作业时,作业人员登梯前应检查梯子是否结实,安放是否牢靠,是否有人扶梯。
1攀杆时,作业人员应戴好安全帽,作业时扎好安全带,
2攀登支柱前,应检查支柱状态,观察支柱上有无其它设备,选好攀登方向和条件。
3攀登支柱时应手把牢靠,脚踏稳准,尽量避开支柱上设备。用脚扣攀登时,脚扣应卡牢,防止滑落。
4使用爬梯作业时,应保证爬梯上部绑扎牢固,并有专人扶持,梯脚应有防滑措施。
5数人同登一根电杆作业时,不得在同一侧上下。
,不得使长大金属体将线路两根钢轨短接,在遇有轨道绝缘节处施工注意不得连接绝缘节两侧。
基础及构支架
:
1施工前,施工单位应与地下设施和设备管理单位签订施工安全协议书,设备管理单位应向施工单位现场划定地下埋设物位置范围。施工单位并按规定逐级交底到施工作业人员;作业时,设备管理单位应进行现场监护和指导。
2上线施工,必须由合格领工人员带领,不
接触网工程安全操作规程 来自淘豆网m.daumloan.com转载请标明出处.