防雷接地论文
论移动通信CDNA网络基站
防雷接地的重要性
职称类型:工程师
单 位:中国电信股份有限公司进贤分公司
姓 名:李火印
摘要:
中国电信于2008年10月1日从中国联通手上接管CDMA网络后,从进贤接管的中国联通的26个基站中发现其CDMA网络与GSM网络共用一套基站系统,其防雷接地系统按GSM网络标准建设,其实 CDMA基站天馈系统的雷电防护与GSM基站明显不同,出现了一些新情况、新问题。从基站天馈系统的防雷保护、基站接地网与接地系统、设备接地及接地线、进站动力电缆的防护等几个方面给出合理可行的防护措施。在后期我们自主建设CDMA3G网络应该参照CDMA新的要求建设,并对与中国联通共站的CDMA3G网络的防雷接地系统进行合理的改造。
China Telecom on October 1, 2008 from China Unicom in taking over the CDMA network, from Jinxian takeover of China Unicom's 26 base found its CDMA network and GSM network share a set of base station system, the lightning protection and grounding system by GSM network standard construction, actually CDMA base station antenna feeder system lightning protection and GSM base station is obviously different, some new situations and new problems. From the base station antenna and feeder system of lightning protection, base stat
ion grounding grid and grounding system and equipment grounding and grounding wire, power cable protection and so on several stops are reasonable and feasible protective measures. In the late period, we should construct the CDMA3G network with reference to the new requirements of CDMA and reform the lightning protection and grounding system of CDMA3G network which is a total station of China Unicom..
关键词:
3G雷电防护措施;基站地网;设备接地;接地线
3G lightning protection measures; base station network; ground wire;
引言:
3G基站防雷接地系统与2G的要求明显要高,重点在于和塔放(RRU)相连的各个线缆及端口,但仅仅做好塔放(RRU)相关端口的保护是不够的,还必须从基站地网、站内等电位联接、进站动力电缆的防护以及站内电源系统雷电过电压保护等多方面进
事故发生的关键,所以防雷问题往往成为BTS设备安装设计中的一个重要问题。对于山区内孤立山上的BTS,雷击事件更为频繁,更应该重视防雷接地系统的设计。
2、防雷接地系统的构成和基本要求
防雷接地系统是由大地、接地电极、接地引入线、地线汇流排、接地配线五部分组成的整体。其中:大地具有导电性和无限大的容电量,是良好的公共地参考电位;接地极是与大地电气接触的金属带等,用于使电流扩散入地;接地引线是在接地电极与室内地线汇流铜排之间起连接作用的部分;地线汇流排为汇集接地配线所用的母线铜排;接地配线是连接设备到地线汇流排的导线。
接地极有垂直打入地下的棒形接地极组(用扁钢或角钢)、钢板接地极组和水平辐射的带状接地极,也有用这几种形式混合组成的复合式地网的。垂直打入地下,然后用导线连接起来的方式比破土