开关测试仪说明书
说明书
JGKC-2006 断路器动特性分析仪
使
用
手
册
说明书
说明书
目录
一、技术参数·····················································1
二、性能特点·····················································1
三、术语定义·····················································2
四、面板布置·····················································
3
五、菜单操作说明·················································4
主菜单设置···············································4
················································5
················································6
················································7
················································8
六、现场接线·····················································8
··············································8
··············································8
七、传感器安装方法···············································8
················································8
················································9
················································9
八、仪器的配套性与售后服务·······································9
九、附录一:测试所得的部份图形和文本结果·························
10
十、附录二:内部电源控制接线图····································11 十一、附录三:断口接线图··········································12 十二、附录四:仪器常见技术问题····································14
说明书
、使用环境
输入电源 220V±10% 50Hz±10% 大气压力 86~106kpa
温度-10~40℃湿度≦80%RH
、安全性能
绝缘电阻>2MΩ
,无闪络与飞弧。
、基本参数
? 时间: 量程
误差①100ms以内 ±1个字
②100ms以上 %±1个字
③同期
? 速度: 量程
误差①0-2m/s以内±±1个字
②100ms以上±±1个字
? 行程:
?
?
?
? 电流: 量程 输出电源: DC30~250V数字可调/20A(瞬时工作) 外形尺寸: 360mm(L)×280mm(W)×300mm(H) 重量: 9kg
二、性能特点
1、性能
? 时间:12个断口的固有分、合闸时间,同相同期、相间同期。
? 重合闸:每断口的合-分,分-合,分-合-分过程时间:一分时间、一合时间、
二合时间、金短时间、无电流时间值。
? 弹跳:每断口的合闸弹跳时间,弹跳次数,弹跳过程,弹跳波形;每断口的分闸
反弹幅值。
? 速度:刚分、刚合速度,最大速度,时间-行程特性曲线。
? 行程:总行程,开距,
开关测试仪说明书 来自淘豆网m.daumloan.com转载请标明出处.