制冷压缩冷凝机组
操
作
使
用
说
明
书
泰州市裕华制冷设备制造有限公司
地址:江苏省泰州市寺巷镇人民路143号电话:0523-86815008
传真:0523-86811970 邮编:225300 电子邮箱:yuhualq@
为了您能更好、更安全、更节能的使用我公司提供给您的制冷压缩冷凝机组,请您仔细阅读本使用说明书!
目录
机组简介
一到货验收··················································3
二设备吊装···················································3
三设备安装··················································4
四制冷管路连接··············································5
五系统电气连接··············································
7
六系统保证(质保说明)·······································8
七设备检查··················································9
八系统操作说明··············································9
九开机程序·················································12
十维护保养·················································13
十一故障与原因及排除方法(故障分析表)······················14
机组简介
制冷压缩机组,是制冷系统的“心脏”。我公司生产的制冷压缩机组选用:
“半封闭活塞式、双螺杆喷油式、全封闭旋涡式、全封闭活塞式压缩机作为主机。
1、机组冷凝方式划分为:风冷冷凝、水冷冷凝、风-水冷和蒸发冷凝四大系列;
2、机组蒸发温度划分为:高温(空调)、中温(-5—0℃冷藏库)低温(-18℃冷冻库)
单机双级速冻(—25至—40℃速冻)四大系列;
机组的压缩机输入功率选择从:2HP至270HP(马力)系列中选取。
以上系列产品可满足所有的高、中、低温,空调、食品冷藏、冷冻、食品陈列柜、制冰机、冷库、速冻库、隧道速冻机、工艺冷却及其它制冷设备的需要。
专业整体化机组设计极大的提高了设备的运行效率,降低了用户的运行成本,提高了核心部件的使用寿命,便于用户的安装、维修和管理。
科学、有效、简洁、可靠的设计加上世界名牌压缩机使得制冷压缩机组成为高质量,性价比最好的制冷机组之一。我们诚信的售后服务保证,解决了客户一切后顾之忧。
对于工程商来说,使用我公司的机组,您必须做好以下六项工作:
(1)检查机组型号、外观、配件、压力是否正常;
(如发现问题请及时与我公司联系)
(2)安装设备(包括设备基础及机房,室外防雨罩棚等);
(3)连接制冷管路;
(4)电气控制连接;
(制冷压缩机组上所有需要外接的电路,出厂前已全部接入接线盒内接线端子上,客户可根据接线图,把线接入控制电柜,如用户需要我公司也可以根据用户要求提供控制电柜)
(5)检漏、打压、抽真空并充注制冷剂;
(6)调试启动运行系统。
以上工作均应在制冷专业人员指导下进行!
制冷压缩机组如出现因制造原因引起质量问题,我公司免费保修一年!
一、到货验收
首先请核对该机组型号是否与订货型号一致。
若到货型号无误,请检验该机组及随机附件是否损坏或丢失。在签署货运收据前应清点装箱清单上的所有物品,将任何丢失或损坏情况记录在货运商的交货单上(详细说明所发现的损坏程度及类型)。应仔细检查隐蔽损坏,并将损坏情况在48小时(不含休息日)内以书面的形式通报给我公司销售部及货运商。立即要求和货运商联合检查(在货运商代表检查完前不要修补机组)。
提醒:
机组检验工作应交给可靠的专业人员。
开箱时应特别小心以防损坏机组。
某些附件,有可能另外封装于一个小包装中。请按照随机发运的装箱清单验收,并确认您已收到了所有的部件。
二、设备吊装
在使用任何工具起吊或叉铲机组前请慎重操作。决不允许将机组倒置或倾斜超过45度!
对于较大机架制冷压缩机组,由于承载起吊负荷的部分仅是经焊接的型钢底座,机组的起吊只允许通过两种方式:
(1)用叉车直接叉该底座,
(2)用索具连接机架四个角落,且索具不允许接触到机组的任何管道、
冷凝器和电气部
制冷压缩机组使用说明书正文(修改版) 来自淘豆网m.daumloan.com转载请标明出处.