企 业标准光伏电站检修规程试行编制:审核:批准:有限公司发布2015-09-发布2015-10-实施目录前言.....................................................................................................................3第一章光伏组件检修规程.................................................................................4第二章直流防雷汇流箱检修规程....................................................................6第三章光伏并网逆变器检修规程..................................................................11第四章变压器检修规程...................................................................................23第五章35KV高压开关柜检修规程.............................................................33第六章二次设备一般性检修规程..................................................................51第七章SVG设备检修规程............................................................................72第八章直流控制电源检修规程......................................................................79第九章站用电系统检修规程..........................................................................90前言本规程是为光伏发电站设备检修编制的技术标准文件,是企业标准化管理体系文件的组成部分。本标准在试行中,发现并提出有待改进的地方恳请指正,以便修正完善。本标准由有限公司提出。本标准由工程管理部归口。本标准起草单位:公司本标准主要起草人:审核:审定:批准:本标准由工程管理部负责解释。本标准2015年9月30日发布,10月1日实施。本标准的版本及修改状态:A/1。。“下列文件中的条款通过本标准的引用而成为本标准的条款。凡是注日期的引用文件,其随后所有的修改单(不包括勘误的内容)或修订版不适用于本标准,凡是不注日期的引用文件,其最新版本适用于本标准。”DL/T838-2003发电企业设备检修导则GB2297-1989太阳光伏能源系统术语GB6495-86地面用太阳电池电性能测试方法GB/T11012-1989太阳电池电性能测试设备检验方法SJ/T2196-:型号SYP260P种类、数量多晶硅、155232最大功率(Pmax)260Wp组件尺寸1650*992*35*30mm开路电压(Voc)>%短路电流(Isc)-%/℃工作电压(Vmppt)-%/℃;工作电流(Imppt)+%/℃%,办理好停电有关手续和工作票手续;、材料、工具、准备好,同时将检修工作程序安排好,并传达到所有参与人员;,力求参加检修工作的人员思想一致,行动统一,分工协作合理,以便高效率完成工作。、损坏情况、设备温度、导线的绝缘老化程度,光伏组件是否被破坏;,将需更换的光伏组件的正负极接线从接头处拔开,卸下固定光伏组件的螺钉,取下光伏组件,安装新更换的光伏组件,装上固定螺钉,安装时应注意光伏组件不应受各方应力,以免光伏组件受应力而损坏,安装完后检查背板接线盒电缆线连接情况,再将正负极接线插入接头,连接时应注意电缆极性;更换工作完毕时,恢复上述措施。此项工作尽量