DIAGNOSTIC UNIT I
LK sensor
Run: IS/RS 2)
UP direction with IS
DOWN direction with IS
Program selector wheel
LN sensor
W/W1 contactor
WO/WU Schütz
Pulses
Check-back SR module
Safety circuit EK
HK
TK
KT
Seven-segment-function display
flashing1)
Start/Stop button
Function 01 00 Display of error stack as per:
显示故障堆栈
Example:
Error
Explanation
Weighting BW
14 03
AAjob-specific error messag任务特性故障信息
N emergency stop 紧急停梯
XX landing 楼层
S stopping 停止
YY undefined 未定义
M spontaneous message 自发信息
NN explanations from page 21 解释见21页
B lift blocked 电梯被锁定
ZZ Number of marking flag 标志编号
..B operation phase
运行阶段
Significance: Frequency levels of error:
含义:故障频繁度
Level 1 infrequent 1度不频繁发生
Error code number 故障代码
Level 10 frequent 10度频繁发生
Error
Error description
Causes, remedy or instructions
BW
01 XX
Interlock contact RK or RKD is jamming in landing XX. 门锁触点RK或RKD在XX楼层处卡住/在XX层检查门锁触点或门的机械部件。在任务特性程序中必须将门的型号编程输入
Check interlock contact or mechanical parts of door in landing XX.
A correct door type must be programmed in the job-specific program.
6
02 01
Calls inhibited via monitoring
召唤因监控作用被禁止
An 8-kbyte RAM is required in CPU. CPU 中需要一块8-KBYTE RAM
1
02 02
Quasi ZSE in lift-specific program released, but Siemens CPU still used.
在电梯特性程序中QUASI的ZSE开关被删掉,但在SIEMENS的CPU中仍使用
Use Thyssen CPU with battery-backed RAM chip (storage of position in the event of power failure or if HS is switched off).用THYSSEN的CPU后备电池的RAM芯片(停电或HS断开时存储位置信息)
1
02 03
TCM control
TCM控制
8 k-RAM not recognized; F8 00 will follow
8K-RAM未识别;随之以F800
1
02 04
TCM control TCM控制
8 k-EPROM not recognized; F8 00 will follow8K-EPRAM未识别;随之以F800
1
02 80
Undefined or wrong operation phase
未定义或错误的运行阶段
1
03 01
No provision has been madefor disconnect landing in lift-specific program.
在电梯特性程序中没有编入关梯楼层
Disconnect landing not programmed (check data sheet) or incorrect order number on lift-specific EPROM. 关梯楼层未编程(检查数据表)或电梯特性EPROM中的定单号不正确
1