化学实验室通风空调自控系统设计和调试.pdf32 暖通空调 HV&AC 2014 年第 44 卷第 12 期设计参考
化学实验室通风空调自控
系统设计和调试
中国食品药品检定研究院于承志☆倪训松△
摘要针对化学实验室空调通风系统的开关控制、风量控制、温湿度控制,从工艺及节能
的角度对自动控制方案的设计和调试进行了阐述。特别是实验室完全变风量和部分变风量两
种设计方案,采用两级控制的思路及方法,既可以实现房间送排风的要求,又能最大限度地降
低能耗。
关键词化学实验室开关控制完全变风量部分变风量文丘里阀通风空调
Automatic control design missioning for chemical
laboratory ventilation and air conditioning system
By Yu Chengzhi ★ and Ni Xunsong
Abstract Aiming at the switch control,air volume control,temperature and humidity control of air
conditioning and ventilation system of chemistry laboratory,analyses the design missioning of
automatic control scheme from the angle of process and energy the full variable air
volume and partial variable air volume two design schemes,adopts two stage control thought and method,
it can realize the room ventilation requirements and minimize the energy consumption.
Keywords chemistry laboratory,switch control,full variable air volume,part of variable air
volume,Venturi valve,ventilation,air conditioning
★ National Institutes for Food and Drug Control,Beijing,China
①
0 引言风机才关。为了方便实验人员操作和物业管理人
近几年,国内许多新建的化学实验大楼采取集员监控,要求每个房间的送排风阀都能做到就地开
中排风和全新风空调两套独立的送排风系统。这关,远程监控。
类实验室采用较多的一种通风方案是竖直集中排 1 .2 设计方案
风,风管竖直安装在排风管井内,排风机安装在屋以每个房间为一个送排风单元,在每个房间送
顶,一个排风机同时负责上下多个楼层多个房间通排风支管与主管的连接处安装一个电动密闭阀,在
风系统的排风。排风设施以通风柜、移动风罩、固门口安装一个送排风启停按钮。当该房间需要启
定风罩和试剂柜为主(见图 1)。用时,就地开启按钮,信号上传到楼宇设备自
化学实验室通风空调自控系统设计和调试 来自淘豆网m.daumloan.com转载请标明出处.